A measured discharge record, with its conditions and limitations. This free example is a fixed snapshot of one test.

Measured capacity3,269 mAh
Measured energy11.95 Wh
Maximum temperature26.5 °C

Recorded summary values, rounded for display. Curve points may be reduced for plotting.

Test conditions

Discharge setting
1 A constant current
Discharge cutoff
2.5 V
Test recorded
2026-06-19
Physical sample
Unassigned
Room temperature
24 °C
Report type
Fixed ordinary-test snapshot

Voltage as capacity is delivered

Voltage as capacity is deliveredVoltage (V) plotted against Delivered capacity (Ah) for this one discharge record.02.40.82.81.63.32.53.83.34.3Delivered capacity (Ah)Voltage (V)
Display reduced to 500 of 2,500 recorded points; endpoints and bucket extremes are retained. Summary values come from the original record.

Temperature during discharge

Temperature during dischargeTemperature (°C) plotted against Elapsed time (minutes) for this one discharge record.021.949.823.199.724.3149.525.5199.426.8Elapsed time (minutes)Temperature (°C)
Display reduced to 500 of 2,500 recorded points; endpoints and bucket extremes are retained. Summary values come from the original record.

What this example tells you

This is one completed constant-current discharge record. It does not establish cell-to-cell variation, pack performance or cycle life. An Unassigned sample label means the record does not identify a particular physical cell.

The settings describe a laboratory test, not an operating or pack-design recommendation. Follow the exact manufacturer’s data sheet and use appropriate BMS protection, insulation, fusing, conductors, current sharing and thermal management. Read our battery safety guidance and test methodology.